COMBI-PRO 2PT
Permanent + Transient + IGA, single-phase, automatic reconnection
Description
Protection against permanent overvoltages caused by increases in the network voltage, and transient overvoltages caused by lightning strikes or network switching in single-phase installations. The equipment will automatically reconnect when the mains voltage is restored within the established limits.
Formed by COMBI-PRO 2PT (IGA + a trip coil with automatic reclosing) + Vigivolt V2T.
SPECIFICATIONS | strong>Values |
---|---|
General | |
Nominal working voltage | 240 VAC |
Frequency | 50-60 Hz |
Consumption | 0,3W |
Maximum terminal section | 25 mm |
Environmental margins | -20º +70º C / 80% R.H. |
Protection | IP20 |
Assembly | Rail DIN 35 |
No. of modules DIN | 5 |
Standards | UNE-EN 60898 / EN 50550 |
strong>Surge>/strong> | |
Trigger voltage | 270VAC ± 2% |
Surge response time | according to EN 50550 |
Rearmament time | 10 seconds |
Reconnection voltage | < 255V ± 2% |
strong>Subvoltage | |
Trigger voltage | <180VAC ± 2% |
Undervoltage response time | 10 seconds |
Rearmament time | 10 seconds |
Reconnection voltage | 210VAC ± 2% |
strong>IGA | |
Nominal intensity | 16-20-25-32-40-50-63A |
Curve | C |
Cutting power | 6 kA |
strong>Others | |
Contact Us | 230VAC 1A / 24Vdc 2A |
Remote control input | 230VAC 1A |
strong>Transitory>/strong> | |
Maximum voltage Uc | 320VAC (L/N) |
Level of protection Up (L/N) | <1,5kV |
Level of protection Up (N/PE) | <1,5kV |
Maximum discharge intensity (8/20µs) Imax (L/N) | 15kA |
Nominal discharge intensity (8/20µs) In (L/N) | 8kA |
Maximum discharge intensity (8/20µs) Imax (N/PE) | 15kA |
Nominal discharge intensity (8/20µs) In (N/PE) | 10kA |
Maximum cable section in terminals | 16mm2 |
Pre-existing protection fuse | 63A gL |
Class / Type | II |
Standards | IEC 61643-11/EN 61643-11 |
>strong>IMPORTANT
Codes and references
10002891 | COMBI-PRO 2P16T15 – Trans. SPD 15kA, perm. POP 240Vac + IGA/MCB 2x16A auto-reconnect |
---|---|
10002892 | COMBI-PRO 2P20T15 – Trans. SPD 15kA, perm. POP 240Vac + IGA/MCB 2x20A auto-reconnect |
10002893 | COMBI-PRO 2P25T15 – Trans. SPD 15kA, perm. POP 240Vac + IGA/MCB 2x25A auto-reconnect |
10002894 | COMBI-PRO 2P32T15 – Trans. SPD 15kA, perm. POP 240Vac + IGA/MCB 2x32A auto-reconnect |
10002895 | COMBI-PRO 2P40T15 – Trans. SPD 15kA, perm. POP 240Vac + IGA/MCB 2x40A auto-reconnect |
10002896 | COMBI-PRO 2P50T15 – Trans. SPD 15kA, perm. POP 240Vac + IGA/MCB 2x50A auto-reconnect |
10002897 | COMBI-PRO 2P63T15 – Trans. SPD 15kA, perm. POP 240Vac + IGA/MCB 2x63A auto-reconnect |